Gửi tin nhắn
MOORE AUTOMATION LIMITED
E-mail miya@mvme.cn ĐT: 86-180-20776792
Nhà > các sản phẩm > Bộ điều khiển GE >
531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'vi', function () {});}
  • 531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'vi', function () {});}

531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'vi', function () {});}

Nguồn gốc Hoa Kỳ
Hàng hiệu GE
Chứng nhận CO.CQ
Số mô hình 531X152IOCAKG1
Thông tin chi tiết sản phẩm
Manufacture Year:
2020
P/N:
531X152IOCAKG1
ứng dụng:
Nuclear Power Plant
Thời gian hoàn thiện:
Trong kho
Mô tả:
GE
Tên:
531X152IOCAKG1 GE Controller Process Interface Board
Điểm nổi bật: 

general electric board

,

ge multilin relaysfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en'

Điều khoản thanh toán & vận chuyển
Số lượng đặt hàng tối thiểu
1
Giá bán
inquiry
chi tiết đóng gói
mới và nguyên bản với nhà máy niêm phong
Thời gian giao hàng
hôm nay
Điều khoản thanh toán
T/T
Khả năng cung cấp
10 miếng mỗi ngày
Mô tả Sản phẩm

 

Product Specification

Brand/Manufacturer GE/USA
Part Number

531X152IOCAKG1

Alternate Part Number  531X152IOCAKG1
Description

Process Interface Board

Dimennsions 3*13*10cm
Weight 0.24kg

 

Product Details
The timer shown in Figure 4.7 is reset on the first scan. On the second scan, it

starts timing. After 5seconds, it energizes a bit called“COMINIT”, which is used

to trigger the COM_REQ. It also energizes a bit called“RTMINIT”. On the next scan,

“COMINIT”is turned off, and the RTMINIT bit causes the timer to be disabled indefinitely.

Temporary (%T) data types are used for these two bits, so that their state is not

retained through a reset.After the COM_REQ has been executed, it writes status

data to the status register specified in theCOM_REQ data block. This register is

monitored by the ladder logic to determine the successful (or unsuccesful) result

of the COM_REQ. It is good practice to clear the status register just prior to execution
of the COM_REQ, ensuring the validity of future data.

 

531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'vi', function () {});} 0            531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'vi', function () {});} 0            

 

More Products

GE DS200LDCCH1A GE 531X133PRUAMG1
GE DS200TBQBG1ACB GE 531X139APMASM7
GE IS2020ISUCG3A GE 531X124MSDAJG2
GE DS200TCDAH1BHE GE 531X300CCHAGM5
GE DS200TCDAH1BHD GE DS200LPPAG1A
GE 531X121PCRALG1 GE IC660CBB902K
GE DS200LPPAG1A GE IC600BF929K
GE IC600FP832K GE IC660FP8900K

 

Contact Us

miya@mvme.cn(Click)

 

Email: miya@mvme.cn                   QQ: 2851195450

Tel: 86-18020776792                     Skype: miyazheng52

Liên lạc chúng tôi bất cứ lúc nào

86-180-20776792
Tầng 32D, tòa nhà GuoMao, Đường Hubin South, Quận Siming, Thành phố Hạ Môn Province Tỉnh Phúc Kiến , Trung Quốc.
Gửi yêu cầu của bạn trực tiếp cho chúng tôi